Table 5 Diagnostic performance of different cut-offs for admission D-dimer values for detecting pulmonary embolism in patients with COVID-19 (n = 155)

From: Predictors of pulmonary embolism in hospitalized patients with COVID-19

D-dimer cut-off (ng/ml)

Sensitivity

Specificity

PPV

NPV

0.50

98.46%

11.11%

44.44%

90.91%

1.00

90.77%

30%

48.36%

81.82%

1.25

86.15%

38.89%

50.45%

79.55%

2.50

61.54%

65.56%

56.34%

70.24%

5.00

50.77%

84.44%

70.21%

70.37%

7.50

49.23%

86.67%

72.73%

70.27%

10.00

46.15%

88.89%

75%

69.57%

15.00

35.39%

92.22%

76.67%

66.40%

20.00

30.77%

93.33%

76.92%

65.11%