Correction to: agitation-dependent biomechanical forces modulate GPVI receptor expression and platelet adhesion capacity during storage
Thrombosis Journal volume 20, Article number: 16 (2022)
Correction to: Thrombosis J 20, 3 (2022).
https://doi.org/10.1186/s12959-021-00359-7
Following publication of the original article [1], it was reported that Fig. 2, Fig. 6 and Table 1 contained several typographical errors. A table header and a label in both figures were incorrectly labelled ‘MAN’ instead of ‘MM’.
GPVI expression in response to different agonists. The representative histograms show different levels of GPVI expression in response to low (1 μM) and high (10 μM) concentrations of potent agonist ionophore A23187 (A) as well as 10 μg/ml collagen (B) in one-day stored CAG platelets. Graph (C) also depicts the significant increments of GPVI in response to collagen in both MM- and GAC- PCs whereas this agonist did not increase GPVI expression in PP2 treated GAG-PCs (all in one-day stored PCs, n = 5). CAG = continuously-agitated; MM = manually-mixed;.PC = platelet concentrate. Note: ns: not significant; *p < 0.05
Platelet adhesion and spreading over collagen matrix in manually mixed and agitated PCs during storage. A provides a demonstrative image characterizing platelets adhesion (marked with a red arrow) versus spreading (marked with a yellow arrow) on collagen matrix. B shows demonstrative images comparing different levels of platelet adhesion and spreading to collagen in one–day stored MM-PCs and CAG-PCs in presence and absence of PP2 treatment. Graph C compares number of adhered platelets among MM-PCs, CAG-PCs and PP2-treated CAG-PCs (n = 10) while D demonstrates different levels of platelet spreading on collagen matrix in each product during storage. CAG = continuouslyagitated; MM = manually-mixed; .PC = platelet concentrate. Note: ns: not significant; *p < 0.05; **p < 0.01
The corrected figures and table are included in this Correction article and the original article [1] has been updated.
Reference
Hosseini E, Solouki A, Haghshenas M, Ghasemzadeh M, Schoenwaelder SM. Agitation-dependent biomechanical forces modulate GPVI receptor expression and platelet adhesion capacity during storage. Thrombosis J. 2022;20(1):3. https://doi.org/10.1186/s12959-021-00359-7.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
About this article
Cite this article
Hosseini, E., Solouki, A., Haghshenas, M. et al. Correction to: agitation-dependent biomechanical forces modulate GPVI receptor expression and platelet adhesion capacity during storage. Thrombosis J 20, 16 (2022). https://doi.org/10.1186/s12959-022-00371-5
Published:
DOI: https://doi.org/10.1186/s12959-022-00371-5